Technical Specifications - Paradyne 3163 User Manual

Paradyne acculink dsu/csu user's guide 3163
Hide thumbs Also See for 3163:
Table of Contents

Advertisement

Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
The technical specifications for the DSU/CSUs are
listed in Table B-1.
Specifications
POWER REQUIREMENTS
Typical:
AC Power Module
Optional:
+24 Vdc
– 48 Vdc
– 48 Vdc Redundant
POWER CONSUMPTION AND
DISSIPATION
NETWORK T1 INTERFACE
Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation
LOOPBACKS
Standard
Additional
PORT INTERFACE
Standards
Rates
3163-A2-GB20-10

Technical Specifications

Table B-1
(1 of 2)
Models 3163 DSU/CSU Technical Specifications
Refer to the labeling on the ac power module for input requirements
+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to – 60 Vdc, 0.25A
–38 Vdc to – 60 Vdc, 0.25A
16.0 watts, 55.0 Btu per hour at 115 volts (ac power); 12.0 watts, 41 Btu per hour
at +24 and – 48 Vdc (dc power)
RJ48C
CA81A using adapter cable
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable
AT&T TR 54016, AT&T TR 62411, ANSI T1.403.1989
RLB (Repeater Loopback), V.54 Loop 2 and Loop 3, ANSI T1.403 Annex B
Fractional T1 Loopback
EIA-530-A, V.35, RS-449, X.21
Nx64 – 64K-1.536 Mb
Nx56 – 56K-1.344 Mb
March 1999