5. From the Send screen, press the Function key that
corresponds to network or the port for which you
want to send a test pattern. Use the scroll keys, if
necessary. (NET does not appear for the 511
pattern.)
Send: Name
NET
F1
The Test Started screen appears.
Send: Name and Dest
Test Started
F1
If the DSU/CSU is already sending the test pattern
you selected, the message Already active appears.
If you attempt to start a different pattern test while
one is active, the message Invld Test Combo
appears.

Monitoring Test Patterns

Use the Monitor command to monitor a QRSS test
pattern over all the channels on the network interface, or
to monitor QRSS or 511 test patterns on the channels
allocated to an individual port.
This command provides the number of errors detected
in the test pattern (5 digits, maximum 99999).
"
Procedure
To monitor a QRSS or 511 test pattern:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk Lpbk
F1
4-16
Prt1
F2
F3
F2
F3
Ptrns
F2
F3
3. From the Patterns screen, select Mon.
4. From the Patterns Mon screen, press F1 for QRSS
or F2 for 511.
5. From the Monitor screen, press the Function key
that corresponds to network or the port for which
you want to send a test pattern. Use the scroll
keys, if necessary. (NET does not appear for the
511 pattern.)
The Monitor screen appears with the error count.
If the maximum of 99999 is exceeded, OvrFlw
appears instead of the count. If the receiver loses
synchronization while the monitor is active, No
Sync appears.
March 1999
Patterns:
Abort
Send
Mon
F3
F1
F2
Patterns: Mon
QRSS 511
F1
F2
F3
Monitor: Name
NET
Prt1
F1
F2
F3
3163-A2-GB20-10