Auxiliary Output Function - Omron F3SJ-B0185P25-01TS User Manual

Safety light curtain
Table of Contents

Advertisement

Auxiliary Output Function

The auxiliary output is used to monitor the status of the F3SJ-B. This output can be connected to a
device such as programmable controller.
Do not use the auxiliary output for safety applications.
Human body may not be detected when F3SJ-B fails, resulting in serious injury.
Unblocked
Unblocked
Blocked
/Blocked
Safety output
Auxiliary output
15 ms
ON
OFF
30 ms max.
ON
OFF
System Configuration and Functions
70 ms
30 ms max.
E
F3SJ-B
15
User's Manual