Testing Guide For Dual-Ended Testing - Viavi Certifier40G User Manual

Fiber certificaton tester
Hide thumbs Also See for Certifier40G:
Table of Contents

Advertisement

Testing Guide for Dual-Ended Testing

1. Connect FC1 to the Local TX port and SC1 to coupler 1.
2. Connect SC5 to the Local RX port and SC6 to coupler 2.
3. Connect FC2 to the Remote TX port and SC2 to coupler 4.
4. Connect SC3 to the Remote RX port and SC4 to coupler 3.
5. Connect the cord to be tested SC7 to coupler 1 and SC8 to coupler 3.
6. Connect the other cord to be tested SC9 to coupler 2 and SC10 to coupler 4.
FC1
SC5
TX
RX
7. Press the AUTOTEST button to begin AUTOTEST.
8. If Bi-Direction measurement is selected, swap the position of SC1 and SC6, SC2 and
SC4.
FC1
SC5
TX
RX
9.
Click "Step 2" to continue test.
SC1
SC7
SC8
SC6
SC9
SC10
SC6
SC7
SC8
SC1
SC9
SC10
SC4
SC2
FC2
SC3
TX
RX
SC2
SC4
FC2
SC3
TX
RX