4. Connect SC3 to the Remote RX port and SC4 to coupler 1.
FC1
SC5
TX
RX
5. Press the AUTOTEST button.
6. Check that the result passes with the following results;
 Single Mode – 0.2 dB
 Multi-Mode - 0.1 dB
 EF compliant Multi-mode – 0.1 dB
For 2 jumpers dual-ended,
1. Connect FC1 to the Local TX port and SC1 to coupler 1.
2. Connect SC5 to the Local RX port and SC6 to coupler 2.
3. Connect FC2 to the Remote TX port and SC2 to coupler 2.
4. Connect SC3 to the Remote RX port and SC4 to coupler 1.
Please ensure the fiber cables are cleaned using the cleaning kit provided in the kit.
FC1
SC5
TX
RX
5. Press the SETUP button > Testing Configuration and select "Two Jumper" from Dual-
Ended column. Select Single or Bi direction depending on requirement.
SC1
SC4
SC6
SC2
FC2
TX
SC1
SC4
SC6
SC2
FC2
TX
SC3
RX
SC3
RX