6-4-4

FZ5-L Series

Cable
• Connect the LAN cable with a straight or cross cable.
• Use an STP (shielded twisted-pair) cable of category 5, 5e, or higher. Applicable EtherNet/IP com-
munications cables and connectors vary depending on the used baud rate.
• For 100Base-TX and 10Base-T, use an STP (shielded twisted-pair) cable of category 5 or higher. You
can use either a straight or cross cable.
• For 1000Base-T, use an STP (shielded twistedpair) cable (double shielding with aluminium tape and
braiding) of category 5e or higher.
I/O Connector
• Electrical specifications: Conforming to IEEE 802.3 standards. Use RJ45 8-pin Modular Connector
(conforming to ISO 8877).
• When selecting a connector, confirm that it is applicable to the cable that will be used. Confirm the
following items: Conductor size, conductor type (solid wire or twisted wire), number of twisted pairs (2
or 4), outer diameter, etc.
Pin Layout
10Base-T and 100Base-TX
1000Base-T
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
Connector pin
Signal name
1
Transmission data +
2
Transmission data -
3
Reception data +
4
Not used.
5
Not used.
6
Reception data -
7
Not used.
8
Not used.
Connector pin
Signal name
1
Communication data DA +
2
Communication data DA -
3
Communication data DB +
4
Communication data DC +
5
Communication data DC -
6
Communication data DB -
7
Communication data DD +
8
Communication data DD -
6 I/O Interface
Abbr.
Signal direction
TD +
Output
TD -
Output
RD +
Input
---
---
RD -
Input
---
---
Abbr.
Signal direction
BI_DA +
Input/output
BI_DA -
Input/output
BI_DB +
Input/output
BI_DC +
Input/output
BI_DC -
Input/output
BI_DB -
Input/output
BI_DD +
Input/output
BI_DD -
Input/output
6
---
---
---
---