Omron fh series Hardware Manual page 152

Vision sensor
Hide thumbs Also See for fh series:
Table of Contents

Advertisement

5 Setup and Wiring
Connection of Terminal Block of FH-L Series
Connect to the terminal block by using the terminal connector, male: FH-XCN-L, which is packaged with
Sensor Controller.
Use the wire of a suitable size (AWG 12 to 16) according to the current consumption. Keep the power
supply wires as short as possible: Max. 2m.
1
Insert the end of the signal line, electric wire, into the terminal block connector (male).
Tighten the three screws on the connector top to secure the wire.
Recommended tightening torque: 0.5 - 0.6 N
2
Insert the terminal block connector (male) into the terminal block connector (female) on the FH
Sensor Controller side.
Power Terminal Con-
3
Secure the terminal block connector (male) by tightening the screws on the right and left sides
of it with a flathead screwdriver. Recommended tightening torque: 0.5 - 0.6 N
4.7
5.08
5 - 12
nector
+
Connect to the DC output terminal +V of 24 VDC.
-
Connect to the DC output terminal -V of 24 VDC.
Connect to the earth.
Terminal block connector (female)
Terminal block connector (male)
15.85
5.08
m
Function
(Unit: mm)
18.2
8.3
Vision System FH/FZ5 series Hardware Setup Manual (Z366)