US
4
TECHNICAL DATA
Mains voltage
Setting range
Permitted load
25 % duty cycle
60 % duty cycle
100% duty cycle
Power factor at max current
Efficiency at maximum current
Open-circuit voltage U
Operating temperature
Transportation temperature
Sound pressure at no load
Nominal flow rate
Dimensions, l x w x h
Weight incl torch and return cable
Insulation class transformer
Enclosure class
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld at a cer
tain load without overloading. The duty cycle is valid for 104° F.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP 23 is designed for indoor and outdoor use.
bp23aa
PowerCut 700
230 V $15 %, 1 ph, 50/60 Hz
30
50 A
37 A
30 A
0.75
80 %
320 V
0
- 50 to 104 °F ( 10 to 40 °C)
- 68 to 131°F ( 20 to 55 °C)
< 49 db (A)
400 cfh at 80 psig(189 l/min at 5.5 bar)
22 x8.3 x15 (557x 211 x 380 mm)
47 lbs (21.3 kg)
H
IP 23
- 9 -
50 A
© ESAB AB 2012