Place the power source at least 3 metres from the cutting area as sparks and slag spray can
damage the power source
5.1

Delivery check and location

1. Remove the packaging. Inspect the equipment for damage that was not
immediately apparent upon reception of the delivery. Immediately report any
damage to the delivery company.
2. Check for any loose parts in the packaging. Check that the air ducts in the
cover's rear panel are not blocked with packaging material that can prevent the
air flow through the power source.
The power source has a carrying handle and can be lifted easily.
3. Position the power source so that its cooling air inlets and outlets are not
obstructed. Minimum permitted distance to wall or other obstruction is 3.3 ft (1 m).
4. An air source that gives clean and dry air, at least 23.8 gallon/l (90 l/m) at
70 psi (4.8 bar), is required for cutting. The cutting air pressure must not exceed
87 psi (6 bar), which is the maximum inlet pressure for the filter regulator that is
included in the delivery.
5.2

Primary power supply

Make sure that the power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. The outlet shall have a protective earth
connection.
Rating plate with supply connection data
bp23aa
- 11 -
© ESAB AB 2012