Service Manual
Model of Outdoor Unit
Outdoor Unit Product Code
Compressor Manufacturer/Trademark
Compressor Model
Compressor Oil
Compressor Type
L.R.A.
Compressor RLA
Compressor Power Input
Overload Protector
Throttling Method
Operation Temp
Ambient Temp (Cooling)
Ambient Temp (Heating)
Condenser Form
Pipe Diameter
Rows-fin Gap
Coil Length (LXDXW)
Fan Motor Speed
Output of Fan Motor
Fan Motor RLA
Outdoor Unit
Fan Motor Capacitor
Air Flow Volume of Outdoor Unit
Fan Type
Fan Diameter
Defrosting Method
Climate Type
Isolation
Moisture Protection
Permissible Excessive Operating Pressure for the
Discharge Side
Permissible Excessive Operating Pressure for the
Suction Side
Sound Pressure Level (H/M/L)
Sound Power Level (H/M/L)
Dimension (WXHXD)
Dimension of Carton Box (LXWXH)
Dimension of Package (LXWXH)
Net Weight
Gross Weight
Refrigerant
Refrigerant Charge
Length
Gas Additional Charge
Outer Diameter Liquid Pipe
Connection
Outer Diameter Gas Pipe
Pipe
Max Distance Height
Max Distance Length
Note: The connection pipe applies metric diameter.
The above data is subject to change without notice; please refer to the nameplate of the unit.
Dalian SANYO Compressor Co.; Ltd.
A
A
W
o
C
o
C
o
C
Aluminum Fin-copper Tube
mm
mm
mm
rpm
W
A
μF
3
m
/h
mm
MPa
MPa
dB (A)
dB (A)
mm
mm
mm
kg
kg
kg
m
g/m
mm
mm
m
m
8
MUCO-60-H6T
UE20391
C-SBP185H38A
FV68S
Scroll
/
9.31
5200
UP18RA052-550
Capillary
16~30
18~43
-7~24
Ф9.52
2-1.4
975X44X813
830
68
0.8
3.5
3600
Axial-flow
Ф472
Automatic Defrosting
T1
I
IPX4
4.3
2.5
62/-/-
72/-/-
1032X1250X412
1100X450X1280
1103X453X1295
114
125
R410A
4.3
5
100
Ф12
Ф19
20
30
Need help?
Do you have a question about the MUCO-H6T and is the answer not in the manual?
Questions and answers