Speed Agreed Signal Output - ACP Speecon 7200M3 Manual

Table of Contents

Advertisement

Functions of control circuit terminals 13 - 7 , and 14 - 7 , can be switched.
Function of terminal between 13 - 7 at "L" :Set into Pn-34 .
Function of terminal between 14 - 7 at "L" :Set into Pn-35 .
Set Value
0(Note 1) Running
1(Note 2) Frequency agreed
2
Zero speed
3
Frequency detection (output frequency ≧ frequency detection level)
4
Overtorque detected
Note: 1. Factory preset value of .
2. Factory preset value of .
˙
Maximum output capacity is 48 VDC 50mA.
˙
To drive an inductive load, be sure to insert a free-wheel diode to control surge voltage.

2.7.17 SPEED AGREED SIGNAL OUTPUT

Item Name
Frequency Detection Level
Multifunction Contact Output Function
Function
Constant to be set
36
34 , 35
- -
91
Factory Preset
0.0 Hz
See page 64