1.4.2 Standard Wiring Diagram

Models with digital operator can be operated from the digital operator (JNEP--13) only by main circuit
wiring. When these models are operated by control circuit terminals, control constant change is required.
For details, refer to RUN STOP PROCEDURE SELECTION" on page 68. Models with analog operator
(JNEP--14) re preset in operation mode from control circuit terminals at the factory prior to shipping.
(1) Run by digital operator
(R)
POWER SUPPLY
(S)
Only terminal R,S
(T)
For single phase series
FWD RUN/STOP
EXT FAULT
JOG REF
EXT.
2kΩ
MASTER
FREQUENCY REF
4 to 20mA
0V
(Digital Operator)
BRAKING RESISTOR UNIT (OPTION)
(R)
(S)
(T)
1
2
3
4
5
6
10
0 to +10V
8
P
9
P
11
Fig 1.2 Standard Wiring Diagram
- -
P
B
B1/P
B2
7200M3
ANALOG
MULT1-FUNCION
CONTACT INPUT
SEQUENCE COMMON (0V)
SHIELDEDTERMINAL
SPEED SETTING POWER SUPPLY+12V 20mA
SPEED REF. 0 - 10V (20kΩ)
4 - 20mA (250Ω)
0V
9
MOTOR
(U)
(V)
(W)
E
GROUNDING
COMPENSATION RESISTOR FOR
12
CONNECT IF NECESSARY
MULTI-FUNCTION ANALOG
+
11
FM
STAND SETTING OUTPUT
FREQUENCY METER
A
B
DEFECTIVE CONTACT OUTPUT
C
13
MULTI-FUNCTION OUTPUT
14
OPEN COLLECTOR 1
MULTI-FUNCTION OUTPUT
OPEN COLLECTOR 2
7
"AGREED FREQUENCY SIGNAL"
IS SET AT FACTORY
IM