2.7.26 FUNCTIONS FOR REDUCTION OF MACHINE
VIBRATION OR SHOCK
The following constants are effective for reduction of vibration or shock.
Effective Method
˙
Shock
˙
To decrease generating torque
˙
To increease generating torque
To reduce shock at acceleration
To reduce shock at deceleration
˙
Vibration
To decrease carrier frequency
Constant
Factory
to be Set
Preset
2 to 8
See page 59 Decrease or increase V/f.
29
1.0
21
0000
9 , 11
10.0s
30
170%
1
0000
21
0000
10 , 12
10.0s
1.5Hz
7
26
50%
4
40
- -
105
Adjustment
Decrease or increase torque boost
Set S-curve accel/decel.
Increase accel time
Increase stall prevention level
during accel.
Set coasting to a stop
Set S-curve accel/decel.
Increase decel time
Decrease or increase minmim
output frequency
Decrease DC injection braking
current.
Decrease PWM carrier frequency
Page
59
81
77
71
82
68
77
71
69
80
89