2.4 CORRECTIVE FUNCTION

2.4.1 Output Frequency Bias (Pn-23) and Gain (Pn-22)

Any desired value of output frequency for frequency set value (0 to 10V or 4 to 20mA) can be set.
Description
Frequency reference value is displayed.
DATA
PRGM
STR
Select PRGM mode.
Pn-01
DRIVE
RESET
Bias)
Select constant (Pn-23 ) (
Pn-23
DATA
STR
Display Pn-23 data.
0.00
Change the set value
DSPL
0.10
Write in the set value. ("End is displayed)
DATA
STR
The data are displayed
0.10
Bias)
Select constant (Pn-23 ) (
RESET
Pn-22
DATA
Display Pn-23 data.
STR
1.00
Change the set value
1.23
Write in the set value. ("End is displayed)
The data are displayed
1.23
123
(Pn-22)= 123
REF. INPUT
LEVEL
BIAS
(Pn-23)=0.1
Key Operation
GAIN
100
GAIN
- -
57
10
Digital Operator Display
LED DRIVE OFF
(10%=0.1)
Displayed for 0.5 second.
Confirm the display.
Remarks