Connecting

6.2 Connecting media modules/SFPs

6.2
Connecting media modules/SFPs
Power supply of the MM900 media modules
The MM900 media modules are supplied with power by the switch.
Power supply of the SFP transceivers
The SFP transceivers are supplied with power via the SFP media module.
6.3

Connecting the grounding

6.3.1

Grounding

Installation on a DIN rail
The device is grounded over the DIN rail.
S7 standard rail
The device is grounded over its rear panel and the neck of the screw.
Wall mounting
The device is grounded by the securing screw in the unpainted hole.
Please note that IE Switches X-300 must be grounded over one securing screw with
minimum resistance.
If an IE Switch X-300 is mounted on a non-conducting base, a grounding cable must be
installed. The grounding cable is not supplied with the device. Connect the paint-free surface
of the IE Switch X-300 to the nearest grounding point using the grounding cable.
19" rack mounting
● 24 V DC variant:
● 100 to 240 V AC variant:
122
Grounding is via the mounting bracket on the device.
The device must be grounded using the grounding bolts on the rear of the device.
Operating Instructions, 10/2010, A5E01113043-10