Siemens SCALANCE X-300 Manual page 277

Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Inserting the IE FC RJ-45 Plug
1. Insert the IE FC RJ-45 Plug in the twisted-pair interface of the IE switch until it locks in
The flush fit and locking mechanism of the PROFINET-compliant IE FC RJ-45 Plug along
with the securing collar on the TP port of the IE Switch guarantee a robust connection
suitable for industrial conditions providing tensile and bending strain relief for the inserted
connector.
The RJ-45 interface of the IE Switch X-300EEC is fitted with a securing bracket instead of a
securing collar. To increase mechanical stability, you can secure the IE FC RJ-45 PLUG to
this securing bracket with a cable binder.
Removing the IE FC RJ-45 Plug
1. Press on the locking lever of the IE FC RJ-45 Plug gently to remove the plug.
If there is not enough space to release the lock with your hand, you can also use a 2.5 mm
screwdriver. You can then remove the IE FC RJ-45 Plug from the twisted pair socket.
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
place.
Figure A-2
Inserting the IE FC RJ-45 Plug (based on the example of the IE FC RJ-45 Plug 180)
Figure A-3
Releasing the RJ-45 plug (based on the example of the IE FC RJ-45 Plug 180)
A.2 Fitting the IE FC RJ-45 Plug
Appendix
277