8.5.3

XR-300M EEC cable lengths

Table 8- 80
Permitted cable lengths (copper)
Device:
SCALANCE
XR324-4M EEC
Table 8- 81
Permitted cable lengths (fiber-optic) Fast Ethernet
Device:
SCALANCE
XR324-4M EEC
Table 8- 82
Permitted cable lengths (fiber-optic) gigabit
Device:
SCALANCE
XR324-4M EEC
Note
Maximum insertion loss of 0.5 dB per SC connector.
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
(Variant)
(-)
(Variant)
(-)
(Variant)
(-)
8.5 XR-300M EEC technical specifications
0 - 55 m
0 - 85 m
IE TP Torsion Cable
IE FC TP
with IE FC RJ-45 Plug
Marine/Trailing/
180
Flexible Cable with IE
or
FC RJ-45 Plug 180
or
0 - 45 m
IE TP Torsion Cable
0 - 75 m
with IE Outlet RJ-45 +
IE FC TP Marine/
10 m TPCord
Trailing/Flexible Cable
+ 10 m TP Cord via IE
FC Outlet RJ-45
Fiber
Note:
The values correspond to those of the permitted MM900 media modules
and SFP transceivers.
Fiber
Note:
The values correspond to those of the permitted MM900 media modules
and SFP transceivers.
Technical specifications
0 - 100 m
IE FC TP standard
cable with IE FC RJ-45
plug 180 or
over IE FC outlet RJ-45
with 0 - 90 m IE FC TP
standard cable + 10 m
TP cord
FO cable length
FO cable length
177