Connecting
6.5 Signaling contact
6.5.2
100...240 V AC / 60...250 V DC (X-300EEC) signaling contact
Danger from line voltage
Devices with this mark have a 100 to 240 V AC power supply.
This product can only function correctly and safely if it is transported, stored, set up, and
installed correctly, and operated and maintained as recommended.
Connecting and disconnecting may only be performed by an electrical specialist.
Connect or disconnect power supply cables only when the power is turned off.
100 to 240 V AC / 60 to 250 V DC signaling contact
The signaling contact has the following switching capacity (resistive load):
● 240 V AC: 1A
● 60 V DC: 1 A
The signaling contact is connected to a 3-pin plug-in terminal block.
Table 6- 9
IE Switch X-300
Pin number
F1
F1
F2
F3
CAUTION
Securing cables with dangerous voltage
Make sure that the connector cannot be released accidentally by pulling on the connecting
cable. Lay the cables in cable ducts or cable channels and secure the cables, where
necessary, with cable ties.
136
WARNING
110 V DC: 0.4 A
250 V DC: 0.15 A
Pin assignment of the 100 to 240 V AC / 60 to 250 V DC signaling contact
F2
F3
Assignment
NC contact
Root
NO contact
Operating Instructions, 10/2010, A5E01113043-10
SCALANCE X-300