Network topologies
3.4 Options of media redundancy
Topology
The following schematic shows a possible topology for devices in a ring with MRP.
Figure 3-6
The following rules apply to a ring topology with media redundancy using MRP:
● All the devices connected within the ring topology are members of the same redundancy
● One device in the ring is acting as redundancy manager.
● All other devices in the ring are redundancy clients.
Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via
a PC with a CP 1616.
Note
SCALANCE X-300 - modular devices (M)
Remember that in the modular switches the ring ports are located on MM900 media
modules.
38
1
5
Example of a ring topology with the MRP media redundancy protocol
domain.
6
2
4
7
8
3
9
10
Operating Instructions, 10/2010, A5E01113043-10
SCALANCE X-300