5.6

Plugging and pulling MM900 media modules

You can use media modules with the following devices:
● SCALANCE XR528-6M
● SCALANCE XR552-12M
Notes on plugging/pulling media modules
NOTICE
Use only approved media modules
In the module slots of the devices, use only approved media modules "MM900" of the
SCALANCE XR-500 IE switches product line.
Note
Slots for PoE modules
You can only use PoE modules in slots 1, 2 and 3, refer to the following section
"Identification of the media module slots and ports".
Note
Factory defaults of the media modules
When inserting a media module, the parameters of the ports are set to the factory defaults.
First plug a media module into the device, and then assign the parameters for the ports.
Note
The names and labeling of the media modules differ
Example: The media module is called MM992-4SFP [6GK5 992-4AS00-8AA0], the labeling
on the media module is 9924AS.
Identification of the media module slots and ports
Below, you can see the arrangement of the slots and ports of a SCALANCE XR552-12M:
Slot
Port
Slot
Port
Slot
Port (SFP+)
Slot
Port
SCALANCE XR-500
Operating Instructions, 09/2018, A5E03275845-12
1
P1
P2
P3
P4
4
P1
P2
P3
P4
7
P1
P2
P3
P4
5.6 Plugging and pulling MM900 media modules
2
P1
P2
P3
P4
5
P1
P2
P3
P4
0
P1
P2
P3
P4
8
P1
P2
P3
P4
Assembling
3
P1
P2
P3
P4
6
P1
P2
P3
P4
9
P1
P2
P3
P4
49

Advertisement

Table of Contents
loading

Table of Contents