Siemens SCALANCE X-300 Manual page 175

Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Device:
Variant
SCALANCE
2 x 100 to 240 V AC, cable outlet front
1 x 24 V DC, cable outlet rear
2 x 24 V DC, cable outlet rear
1 x 100 to 240 V AC, cable outlet rear
2 x 100 to 240 V AC, cable outlet rear
Table 8- 73
Electrical data: Power supply voltage
Device:
Variant
SCALANCE
XR324-4M EEC
1 x 24 V DC, cable outlet front
2 x 24 V DC, cable outlet front
1 x 100 to 240 V AC, cable outlet front
2 x 100 to 240 V AC, cable outlet front
1 x 24 V DC, cable outlet rear
2 x 24 V DC, cable outlet rear
1 x 100 to 240 V AC, cable outlet rear
2 x 100 to 240 V AC, cable outlet rear
Table 8- 74
Power supply voltage
24 V to 48 V DC
100 V to 240 V AC
60 V to 250 V DC
Table 8- 75
24 V to 48 V DC
100 V to 240 V AC
60 V to 250 V DC
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
Plug-in terminal block for connecting:
Power supply
single
Redundant
Power
input
No
Yes
No
Yes
No
Yes
No
Yes
Current consumption and power loss
Current consumption
1.6 A at 24 V
0.75 A at 48 V
0.4 A at 100 V
0.18 A at 240 V
0.7 A at 60 V
0.17 A at 250 V
Electrical data: Overcurrent protection
8.5 XR-300M EEC technical specifications
Power supply
redundant
-
-
-
-
-
Power supply voltage
Power
24 to 48 V DC
supply
units
No
No
No
-
Yes
-
No
No
No
-
Yes
-
Power loss
40 W
42 W
42 W
Overcurrent protection at input
Non-replaceable fuse (F)
T2H / 250 V
T2H / 250 V
T2H / 300 V
Technical specifications
Signaling contact
2 x 2-pin
1 x 2-pin
2 x 2-pin
1 x 2-pin
2 x 2-pin
100 to 240 V AC / 60 to
250 V DC
-
-
-
-