Siemens siprotec 7SA6 User Manual page 760

Distance protection
Hide thumbs Also See for siprotec 7SA6:
Table of Contents

Advertisement

Appendix
F.No.
Description
1511
Thermal Overload Protection OFF
(Th.Overload OFF)
1512
Thermal Overload Protection
BLOKKED (Th.Overload BLK)
1513
Thermal Overload Protection
ACTIVE (Th.O/L ACTIVE)
1515
Th. Overload: Current Alarm (I
alarm) (Th.O/L I Alarm)
1516
Th. Overload Alarm: Near Thermal
Trip (Th.O/L Θ Alarm)
1517
Th. Overload Pickup before trip
(Th.O/L Pickup)
1521
Th. Overload TRIP command (Th.O/
L TRIP)
2054
Emergency mode (Emer. mode)
2701
>AR: Switch on auto-reclose func-
tion (>AR on)
2702
>AR: Switch off auto-reclose func-
tion (>AR off)
2703
>AR: Block auto-reclose function
(>AR block)
2711
>External start of internal Auto
reclose (>AR Start)
2712
>AR: External trip L1 for AR start
(>Trip L1 AR)
2713
>AR: External trip L2 for AR start
(>Trip L2 AR)
2714
>AR: External trip L3 for AR start
(>Trip L3 AR)
2715
>AR: External 1pole trip for AR start
(>Trip 1pole AR)
2716
>AR: External 3pole trip for AR start
(>Trip 3pole AR)
2727
>AR: Remote Close signal (>AR
RemoteClose)
2731
>AR: Sync. release from ext. sync.-
check (>Sync.release)
2737
>AR: Block 1pole AR-cycle
(>BLOCK 1pole AR)
2738
>AR: Block 3pole AR-cycle
(>BLOCK 3pole AR)
2739
>AR: Block 1phase-fault AR-cycle
(>BLK 1phase AR)
2740
>AR: Block 2phase-fault AR-cycle
(>BLK 2phase AR)
2741
>AR: Block 3phase-fault AR-cycle
(>BLK 3phase AR)
B-36
Function
Type of
Information
Thermal Overload OUT
Thermal Overload OUT
Thermal Overload OUT
Thermal Overload OUT
Thermal Overload OUT
Thermal Overload OUT
Thermal Overload OUT
Backup overcur-
OUT
rent
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Automatic Reclo-
SP
sure
Log-Buffers
Configurable in Matrix
ON
*
LED
OFF
ON
ON
LED
OFF
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
*
ON
M
LED
ON
ON
LED
OFF
OFF
*
*
LED BI
*
*
LED BI
ON
*
LED BI
OFF
*
ON
LED BI
*
ON
LED BI
*
ON
LED BI
*
ON
LED BI
*
ON
LED BI
*
ON
LED BI
*
ON
LED BI
*
*
LED BI
ON
*
LED BI
OFF
ON
*
LED BI
OFF
ON
*
LED BI
OFF
ON
*
LED BI
OFF
ON
*
LED BI
OFF
IEC 60870-5-103
BO
167 11
1
GI
BO
167 12
1
GI
BO
167 13
1
GI
BO
167 15
1
GI
BO
167 16
1
GI
BO
167 17
1
GI
BO
167 21
1
BO
128 37
1
GI
BO
40
1
1
BO
40
2
1
BO
40
3
1
GI
BO
40
11
2
GI
BO
40
12
2
GI
BO
40
13
2
GI
BO
40
14
2
GI
BO
40
15
2
GI
BO
40
16
2
GI
BO
40
22
2
GI
BO
40
31
2
GI
BO
40
32
1
GI
BO
40
33
1
GI
BO
40
34
1
GI
BO
40
35
1
GI
BO
40
36
1
GI