Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Steering by High Priority Steering Device – Closed Loop
Symbol
HPStdDisabledAtBootUp
HpStd means High Priority Steering Device.
If the device disable functionality is not desired, the parameter shall be 0.
76 |
©
Danfoss | May 2016
Device Diagnostic Operation
The steering device diagnostic checks are performed both when the device is enabled and disabled.
Enable or Disable Joystick Steering Device
The device enable/disable control is executed by means of the DisableSteeringDevice command (see
PVED-CL Communication Protocol Technical Information, 11079551) from e.g. the man machine interface.
The DisableSteeringDevice command options are:
•
Arm joystick enable/disable
•
Enable joystick
•
Disable joystick
The enabling or disabling of a steering device must follow the state transition sequence shown below in
order to minimize undesired enabling or disabling of a steering device.
control byte = Arm device enable
timeout or incorrect control byte
Device disabled
control byte = Disable device
Disabled at power-up = TRUE
The states, device enabled armed and device disabled armed are volatile states. A transition from these
states to the desired state requires reception of a command message within 200 ms after the reception of
first command message. Otherwise the device disable state will change back to its last state.
Boot-up State of Steering Device
The boot-up enable/disable state of the device can be configured with a parameter and can be changed
via the SetParameter command (see PVED-CL Communication Protocol Technical Information, 11079551).
Index
64008
Getting the Actual Enable/disable Status of the Device
The PVED will send one DisableSteeringDeviceResponse reply message to each DisableSteeringDevice
command it receives (or on time-out), containing the present enable/disable state for all steering devices.
This reply may be used by the MMI for acknowledge or display purposes (see PVED-CL Communication
Protocol Technical Information, 11079551).
The device enable/disable present status for all devices is also transmitted periodically in the
OperationStatus message which is transmitted on the CAN bus by default (see PVED-CL Communication
Protocol Technical Information, 11079551).
Device enabled
armed
control byte = Enable device
Device enabled
timeout or incorrect control byte
control byte = Arm device disable
Device disabled
armed
Disabled at power-up = FALSE
Default
Value range
0
0 (FALSE), 255 (TRUE)