Danfoss pved-cl Operation Manual page 115

Ectro-hydraulic steering version 1.38
Hide thumbs Also See for pved-cl:
Table of Contents

Advertisement

Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Appendix
Name
Data type
Steering Motion
SIGNED16
Threshold
P_Ve_Transit_Threshold
SIGNED16
©
Danfoss | May 2016
Description of parameter
Active State speed threshold.
Detection of steering request with
a steering device (% • 10 of
maximum activation speed)
Vehicle speed Threshold value to
allow new programs to be used for
steering. (km/h • 10)
Steeri
Steering device
External
ng
set-point
High
Low
wheel
controller
Priority
Priority
119
319
419
519
127
327
427
527
11025583 | AQ00000216en-US0302 | 115
Range
Default
[0; 2000]
{50, 100,
100, 100}
[0; 1000]
50