Danfoss pved-cl Operation Manual page 108

Ectro-hydraulic steering version 1.38
Hide thumbs Also See for pved-cl:
Table of Contents

Advertisement

Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Appendix
Index
Name
932
Temperature histogram
interval 1
933
Temperature histogram
interval 2
934
Temperature histogram
interval 3
935
Temperature histogram
interval 4
936
Temperature histogram
interval 5
937
Temperature histogram
interval 6
938
Temperature histogram
interval 7
939
Temperature histogram
interval 8
940
Temperature histogram
interval 9
941
Temperature histogram
interval 10
942
Temperature histogram
interval 11
943
Temperature histogram
interval 12
944
Temperature histogram
interval 13
945
Temperature histogram
interval 14
946
Temperature histogram
interval 15
947
Temperature histogram
interval 16
948
Temperature histogram
interval 17
949
Temperature histogram
interval 18
950
Temperature histogram
interval 19
951
Temperature histogram
interval 20
63000
- not used -
-
20 general purpose
63019
storage parameters
108 |
©
Danfoss | May 2016
Description
Number of 6. minute ticks where the
PVED-CL is operating in temperature
interval :
1 : < -40 deg. C
2 : [-40; -31] deg. C
3 : [-30; -21] deg. C
4 : [-20; -11] deg. C
5 : [-10; -9] deg. C
6 : [ 0; 9] deg. C
7 : [ 10; 19] deg. C
8 : [ 20; 29] deg. C
9 : [ 30; 39] deg. C
10: [ 40; 49] deg. C
11: [ 50; 59] deg. C
12: [ 60; 69] deg. C
13: [ 70; 79] deg. C
14: [ 80; 89] deg. C
15: [ 90; 99] deg. C
16: [100; 109] deg. C
17: [110; 119] deg. C
18: [120; 129] deg. C
19: [130; 139] deg. C
20: > 140 deg. C
The temperature measured on the
PVED-CL printed circuit as long as
the PVED-CL is powered. Read only
- user defined -
Data
Range
Default
Type
U32
[0 ; 4294967295]
U32
[0 ; 4294967295]
0
Locked
Not
Restored