Danfoss pved-cl Operation Manual page 103

Ectro-hydraulic steering version 1.38
Hide thumbs Also See for pved-cl:
Table of Contents

Advertisement

Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Diagnostic & Troubleshooting
Accessing fault codes in the PVED-CL
Available J1939 Diagnostic Trouble Codes
SPN
Description
1083
AD1 short-circuit to GND
1083
AD1 short-circuit to VCC
1084
AD2 short-circuit to GND
1084
AD2 short-circuit to VCC
611
Missing sensor set-points
612
Redundant wheel angle sensor values deviate too
much or CAN sensor set-point data out of range
613
Steering wheel speed plausibility check failure
84
Vehicle speed CAN sensor data plausibility check
failure
©
Danfoss | May 2016
The PVED operation status is the status reflected in the OperationStatus message (see PVED-CL
Communication Protocol Technical Information, 11079551) which is transmitted cyclically on the CAN
bus. If the PVED operation status is not available, check the LED diagnostic,
Lamp
FMI
CM
Status
Red/Amber 4
0
3
0
4
0
3
0
14
0
14
0
Red
14
0
Red/Amber 12
0
LED Diagnostic
OC
Corresponding
PVED-CL Error Code
Yes
10106
Yes
10108
Yes
10107
Yes
10109
Yes
10210,
10212-10215,
10218-10221,
10223-10226,
10229-10231
Yes
10104, 10105, 10232,
10234-10238
Yes
13063
Yes
10217
10228
11025583 | AQ00000216en-US0302 | 103
on page 106.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents