Model Information - Eaton 9910 User Manual

Powerware series
Hide thumbs Also See for 9910:
Table of Contents

Advertisement

Table 3. Control Screens (continued)
Control Screen
Load segments
Restore factory settings
Description
Load segment 1: on | off
Load segment 2: on | off
These on/off commands override automatic load segment on/off controls made by the
Automatic Start Delay and Automatic On Battery Shutdown settings. See "Configuring
Load Segments" on page 31.
Restore Factory Settings: yes | no
Available only in Standby mode. Restoring the factory settings:
S Returns all user-configurable EEPROM settings to default factory settings
S Resets all pending on/off commands
S Clears the alarm history and resets all statistic values and time stamps
S Resets the battery test status
S Initiates the Self Diagnostics test

Model Information

The model information screens display the following UPS information:
S
Model/Type: Chassis style and supply power rating
S
Part Number, SN: Part number and serial number for the UPS
S
NMC firmware: Firmware version for the network management card
S
NMC IP address: IP address for the network management card
S
Comm firmware: (6000 VA models only) Firmware version for the
second processor on the UPS
S
UPS firmware: Firmware version for the primary processor on the UPS
NOTE The network management card firmware screens are displayed only if a Network
Management Card is installed. See "Communication Cards" on page 40.
Eaton 9910 UPS and EBM User's Guide
OPERATION
S
P-164000005 Rev 2
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents