Chapter 4 To Set the Sample System
(option).
For digital channels:
― When 8 channels are enabled, the memory depths available include Auto,
6kPoints, 60kPoints, 600kPoints, 6MPoints, 12MPoints and 24MPoints
(option).
― When 16 channels are enabled, the memory depths available include Auto,
3kPoints, 30kPoints, 300kPoints, 3MPoints, 6MPoints and 12MPoints
(option).
Note: In "Auto" mode, the oscilloscope selects the memory depth automatically
according to the current sample rate.

Antialiasing

At slower sweep speed, the sample rate is reduced and a dedicated display algorithm
can be used to minimize the possibility of aliasing.
Press Acquire  Anti-aliasing to enable or disable the antialiasing function. By
default, antialiasing is disabled and waveform aliasing is more possible.