Sign In
Upload
Manuals
Brands
Mitsubishi Manuals
Controller
Q64DA
Mitsubishi Q64DA Manuals
Manuals and User Guides for Mitsubishi Q64DA. We have
2
Mitsubishi Q64DA manuals available for free PDF download: User Manual
Mitsubishi Q64DA User Manual (186 pages)
Digital-Analog Converter Module
Brand:
Mitsubishi
| Category:
Media Converter
| Size: 3.11 MB
Table of Contents
Safety Precautions
3
Revisions
6
Table of Contents
9
About Manuals
12
Compliance with the EMC and Low Voltage Directives
12
About the Generic Terms and Abbreviations
13
Product Structure
14
Overview
15
Features
15
Functions Added to Function Version B and Later
17
System Configuration
19
Applicable Systems
19
Precautions on System Configuration
22
How to Check the Function Version and Software Version
23
Specifications
25
Performance Specifications
25
Performance Specifications List
25
I/O Conversion Characteristics
27
Accuracy
34
Conversion Speed
34
D/A Converter Module Function
35
Synchronous Output Function
35
Analog Output HOLD/CLEAR Function
36
Analog Output Test During Programmable Controller CPU STOP
37
I/O Signals for the Programmable Controller CPU
38
List of I/O Signals
38
Details of I/O Signals
39
Buffer Memory
43
Buffer Memory Assignment (Q62DAN/Q62DA)
43
Buffer Memory Assignment (Q64DAN/Q64DA)
45
Buffer Memory Assignment (Q68DAVN/Q68DAV)
47
Buffer Memory Assignment (Q68DAIN/Q68DAI)
49
D/A Conversion Enable/Disable (Buffer Memory Address 0: Un\G0)
51
Digital Values (Buffer Memory Addresses 1 to 8: Un\G1 to Un\G8)
51
Set Value Check Codes (Buffer Memory Addresses 11 to 18: Un\G11 to Un\G18)
52
Error Codes (Buffer Memory Address 19: Un\G19)
52
Setting Range (Buffer Memory Address 20, 21: Un\G20, Un\G21)
53
Offset/Gain Setting Mode and Offset/Gain Specification
53
(Buffer Memory Addresses 22, 23: Un\G22, Un\G23)
53
Setting Value Specification (Buffer Memory Address 24: Un\G24)
53
Mode Switching Setting (Buffer Memory Addresses 158, 159: Un\G158, Un\G159)
54
Pass Data Classification Setting (Buffer Memory Addresses 200: Un\G200)
54
(Q62DAN, Q64DAN, Q62DA, Q64DA Only)
54
Industrial Shipment Settings and User Range Settings Offset/Gain Values
55
(Buffer Memory Addresses 202 to 233: Un\G202 to Un\G233)
55
Setup and Procedures before Operation
56
Handling Precautions
56
Part Identification Nomenclature
58
Wiring
60
Wiring Precautions
60
External Wiring
61
Switch Setting for Intelligent Function Module
63
Offset/Gain Settings
67
UTILITY PACKAGE (GX Configurator-DA)
73
Utility Package Functions
73
Installing and Uninstalling the Utility Package
74
Handling Precautions
74
Operating Environment
76
Utility Package Operation
78
Common Utility Package Operations
78
Operation Overview
81
Starting the Intelligent Function Module Utility
83
Initial Setting
86
Auto Refresh Setting
87
Monitor/Test
89
Monitor/Test Screen
89
Offset/Gain Setting Operation (Function Version C or Later)
92
Offset/Gain Setting Operation (Function Version B or Earlier)
94
Confirmation of Conversion Characteristic
96
Pass Data (Q62DAN/Q64DAN/Q62DA/Q64DA)
98
Pass Data (Q68DAVN/Q68DAIN/Q68DAV/Q68DAI)
100
FB Conversion of Initial Setting/Auto Refresh Setting
101
Usage of FB
102
Outline
102
Paste an FB to a Sequence Program
104
Convert (Compile) a Sequence Program
105
Programming
107
For Use in Normal System Configuration
107
Programming Example Using the Utility Package
108
Programming Example Without Using the Utility Package
110
For Use on Remote I/O Network
112
Programming Example Using the Utility Package
113
Programming Example Without Using the Utility Package
116
Online Module Change
118
Online Module Change Conditions
119
Online Module Change Operations
120
Online Module Change Procedure
121
When Industrial Shipment Setting Is Used and Initial Setting was Made with GX Configurator-DA
121
When Industrial Shipment Setting Is Used and Initial Setting was Made with Sequence Program
126
When User Range Setting Is Used and Initial Setting was Made with GX Configurator-DA
131
(Other System Is Available)
131
When User Range Setting Is Used and Initial Setting was Made with GX Configurator-DA
136
(Other System Is Unavailable)
136
When User Range Setting Is Used and Initial Setting was Made with Sequence Program
142
(Other System Is Available)
142
When User Range Setting Is Used and Initial Setting was Made with Sequence Program
147
(Other System Is Unavailable)
147
Range Reference Table
148
Precautions for Online Module Change
153
Troubleshooting
154
Error Code List
154
Troubleshooting
155
When the "RUN" LED Is Flashing or Turned off
155
When the "ERROR" LED Is on or Flashing
155
When an Analog Output Value Is Not Output
156
When Analog Output Value Is Not Held
157
Checking the D/A Converter Module Status Using GX Developer System Monitor
157
Appendix
159
Appendix 1 Function Upgrade for the D/A Converter Module
159
Appendix 1.1 a Comparison of Functions of the D/A Converter Module
159
Appendix 1.2 Combinations of D/A Converter Module Functions and GX Configurator-DA Software Versions
160
Appendix 1.3 Precautions for Replacing the Module of Function Version a with the One of Function Version B or Later
161
Appendix 1.4 Precautions for Replacing Q62DA/Q64DA/Q68DAV/Q68DAI with Q62DAN/Q64DAN/Q68DAVN/Q68DAIN
162
Appendix 2 Dedicated Instruction List and Available Devices
163
Appendix 2.1 G(P).OFFGAN
163
Appendix 2.2 G(P).OGLOAD
166
Appendix 2.3 G(P).OGSTOR
171
Appendix 3 External Dimension Diagram
177
Advertisement
Mitsubishi Q64DA User Manual (86 pages)
Logic, MELSEC-1 Series
Brand:
Mitsubishi
| Category:
Controller
| Size: 0.88 MB
Table of Contents
Safety Precautions
2
Revisions
5
Table of Contents
6
Conformation to the EMC Directive and Low Voltage Instruction
9
About the Generic Terms and Abbreviations
9
Product Structure
10
1 Overview
11
Features
11
Functions Added by Function Version B
12
2 System Configuration
13
Applicable Systems
13
How to Check the Function Version and Software Version
15
3 Specifications
17
Performance Specifications
17
Performance Specifications List
17
I/O Conversion Characteristics
18
Accuracy
25
Conversion Speed
25
D/A Conversion Module Function
26
Synchronous Output Function
26
Analog Output HOLD/CLEAR Function
27
Analog Output Test During PLC CPU STOP
28
I/O Signals for the PLC CPU
29
List of I/O Signals
29
Details of I/O Signals
30
Buffer Memory
33
Buffer Memory Assignment
33
D/A Conversion Enable/Disable (Buffer Memory Address 0: Un\G0)
34
CH Digital Values (Buffer Memory Addresses 1 to 8: Un\G1 to Un\G8)
34
CH Set Value Check Codes (Buffer Memory Addresses 11 to 18: Un\G11 to Un\G18)
35
Error Codes (Buffer Memory Address 19: Un\G19)
35
Setting Range (Buffer Memory Address 20 and 21: Un\G20 and Un\G21)
36
Offset/Gain Setting Mode and Offset/Gain Specification (Buffer Memory Addresses 22 and 23: Un\G22 and Un\G23)
36
Setting Value Specification (Buffer Memory Address 24: Un\G24)
36
4 Setup and Procedures before Operation
37
Handling Precautions
37
Part Identification Nomenclature
39
Wiring
41
Wiring Precautions
41
External Wiring
42
Switch Setting for Intelligent Function Module
44
Offset/Gain Settings
47
5 UTILITY PACKAGE (GX Configurator-DA)
50
Utility Package Functions
50
Installing and Uninstalling the Utility Package
51
User Precautions
51
Operating Environment
53
Explanation of Utility Package Operation
54
How to Perform Common Utility Package Operations
54
Operation Overview
57
Starting the Intelligent Function Module Utility
59
Initial Setting
61
Automatic Refresh Settings
62
Monitor/Test
64
Monitor/Test Screen
64
Offset/Gain Setting Operation
67
6 Programming
68
Programming Example Using the Utility Package
69
Operating the Utility Package
69
Programming Example
70
Programming Example Without Using the Utility Package
71
7 Troubleshooting
73
Error Code List
73
Troubleshooting
74
When the "RUN" LED Is Flashing or Turned off
74
When the "ERROR" LED Is on or Flashing
74
When an Analog Output Value Is Not Output
75
Checking the D/A Conversion Module Status Using GX Developer System Monitor
76
Appendix
78
Appendix 1 Function Upgrade for the D/A Conversion Module
78
Appendix 1.1 a Comparison of Functions of the D/A Conversion Module
78
Appendix 1.2 Combinations of Functions of the Function Version B D/A Conversion Module
78
And the GX Configurator-DA Software Version
78
Appendix 1.3 Precautions When Replacing the Function Version a Module with Function Version B
79
Appendix 2. External Dimension Diagram
80
Index
82
Advertisement
Related Products
Mitsubishi Q64DAN
Mitsubishi q64rd
Mitsubishi q64rd-g
Mitsubishi Q64TCRT
Mitsubishi Q64TCRTBW
Mitsubishi Q64AD-DGH
Mitsubishi Q64AD-GH
Mitsubishi Q64TD
Mitsubishi Q64TDV-GH
Mitsubishi Q64TD-U-H-JE
Mitsubishi Categories
Air Conditioner
Controller
Projector
Automobile
Engine
More Mitsubishi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL