Genie Z80/60 Service Manual page 225

Hide thumbs Also See for Z80/60:
Table of Contents

Advertisement

June 2011
REV C
Error Source
TURNTABLE ROTATE
JOYSTICK
TURNTABLE ROTATE
BUTTONS
TURNTABLE ROTATE
SPEED
TURNTABLE ROTATE FLOW
VALVE
TURNTABLE ROTATE CW
VALVE
TURNTABLE ROTATE CCW
VALVE
TURNTABLE LEVEL
SENSOR X-DIRECTION
TURNTABLE LEVEL
SENSOR Y-DIRECTION
PLATFORM LEVEL SENSOR
Y-DIRECTION
Part No. 88619
Error Type
Value at 5.0 V
Value too high
Limited speed and direction frozen at
zero and neutral, alarm sounds.
Value too low
Value at 0 V
Joystick speed and direction frozen at
Not calibrated
Initiate one second beep of audible
Just calibrated
Fault Check, (both
Turntable rotate disabled, display
buttons pressed)
Display message on LCD and allow
Not calibrated
operation at default speed.
Normal function except threshold for
Not calibrated
one or the other direction is zero.
Display message on LCD.
Initiate one second beep of audible
Just calibrated
Value at 5.0 V
Value Too High
Limited speed and direction frozen at
zero and neutral, alarm sounds.
Value Too Low
Value at 0 V
Limited speed and direction frozen at
Fault check
zero and neutral, alarm sounds.
Display message on LCD and sound
Fault check
Z-80/60
CONTROL SYSTEM FAULT CODES
Effects
zero and neutral.
warning device.
message on LCD.
warning device.
audible alarm.
Section 5 • Fault Codes
Recovery Actions
Power up controller with problem
corrected.
Calibrate joystick.
Self-clearing (transient)
Power up controller with the problem
corrected.
Perform auto calibrate procedure.
Calibrate thresholds.
Self-clearing (transient)
Power up controller with the problem
corrected.
Power up controller with the problem
corrected.
Correct problem.
Continued on next page
5 - 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents