ENV - Set Environment
6
6-4
Remote Start Method Switch [G/M/B/N] = B?
The Remote Start Method Switch is used when the MVME2300
is cross-loaded from another VME-based CPU, to start
execution of the cross-loaded program.
Use the Global Control and Status Register to
G
pass and start execution of the cross-loaded
program. This selection is not applicable to the
MVME2300 boards.
Use the Multiprocessor Control Register (MPCR)
M
in shared RAM to pass and start execution of the
cross-loaded program.
Use both the GCSR and the MPCR methods to
B
pass and start execution of the cross-loaded
program. (Default)
Do not use any Remote Start Method.
N
Probe System for Supported I/O Controllers [Y/N] = Y?
Accesses will be made to the appropriate system
Y
buses (e.g., VMEbus, local MPU bus) to
determine the presence of supported controllers.
(Default)
Accesses will not be made to the VMEbus to
N
determine the presence of supported controllers.
Auto-Initialize of NVRAM Header Enable [Y/N] = Y?
NVRAM (PReP partition) header space will be
Y
initialized automatically during board
initialization, but only if the PReP partition fails
a sanity check. (Default)
NVRAM header space will not be initialized
N
automatically during board initialization.