Boiler drawings key

1. Boiler drum
2. Loading door
3. Ash-pan door
4. Ventilator
- pressure
- extraction
5. Heatproof shaped piece - nozzle
6. Control panel
7. Safety thermostat for pump - 95°C (only for
DC75SE)
8. Control valve
9. Heat proof shaped piece – for type GS
- combustion area side
10. Heat proof shaped piece – for type GS
- spherical space
11. Sealing – nozzle - 12x12 (14 x 14)
12. Heatproof shaped piece – half moon
13. Ignition valve
14. Heat proof shaped piece – for type GS
- rear head of spherical space
15. Cleaning lid
16. Screen
17. Ignition valve pulling rod
18. Thermometer
19. Combustion area screen
20. Switch with an indicator light
22. Draught regulator - Honeywell FR 124
23. Cooling loop protecting against overheating

Technical data

Di-
DC15E
men-
DC20GS DC22SX DC22S DC25S DC30SX
DC18S
sions
A
1180 1260 1180 1180 1180 1180 1260 1260 1260 1260 1410 1360 1360 1260 1380 1480
690
B
770
770
770
C
590
670
590
D
872
946
872
E
152
152
152
F
65
75
65
G
200
180
200
H
930 1000 930
CH
220
255
220
I
190
240
190
J
6/4" 6/4" 6/4" 6/4" 6/4" 6/4" 6/4" 6/4" 6/4" 6/4"
Instruction manual - GB
DC32S
DC30SE
970
970
970
970
590
590
590
670
872
872
872
946
152
152
152
152
65
65
65
75
200
200
200
180
930
930
930 1000 1000 1000 1000 1137 1100 1100 1000 1230 1100
220
220
220
255
190
190
190
240
www.atmos.cz
24. Ventilator control thermostat (boiler)
25. Door filling - Sibral
26. Door sealing – cord 18 x 18
27. Ceramics - roof
28. Switching thermostat for pump - (only for
DC75SE)
29. Ventilator condenser
31. Heatproof shaped piece – half moon
32. Heatproof shaped piece – combustion area
plate 33.
34. Cleaning aperture (DC70S)
35. Waste gas thermostat
36. Safety thermostat
Caution – in overheat condition must be de-
pressed)
37. Brake valve (only for DC40SE, DC50SE,
DC75SE)
38. Spherical space D15 (P) – for DC15E
39. Spherical space lining for DC15E
40. Pump thermostat for DC15E
41. Combustion area screen – rear (model DCXX-
SE) K – flue gas duct neck
L - water outlet from
M - boiler – water inlet to
N - boiler – filling valve
P - pipe sleeve – sleeve for cooling loop control
valve sensor (TS 130, STS 20)
DC40SX DC25GS DC32GS DC40GS DC40SE DC50SE DC50S
970
970
970
970
670
670
670
670
946
946
946 1092 1046 1046 946 1100 1153
152
152
152
152
75
75
75
75
180
180
180
180
255
255
255
255
240
240
240
240
2"
DC70S
DC 80
970 1170 1170 1140 1470
770
770
670
670
152
152
152
180
75
75
75
90
180
180
180
325
305
305
255
0
290
290
240
240
2"
2"
2"
2"
DC75SE
770
180
75
180
305
290
2"
GB-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents