26. Operating a system with accumulation tanks

Ignite the boiler and allow the accumulation tanks to "charge" to the required water temperature
of 90-100°C by the boiler's maximum output operation (2 to 4 loads). Then leave the boiler to stop
burning. Then keep withdrawing heat from the storage utilising three-way valve for a period of time
corresponding to the size of accumulation tanks and the external temperature. In the heating season
(and if adhering to specified min. accumulation tanks volumes – see chart) this could take 1 – 3 days.
If the accumulation method cannot be used, then we recommend using at least one tank of 500 - 1000
l volume for equalising the boiler start-ups and run-outs.
RECOMMENDED MINIMUM ACCUMULATION TANK VOLUMES
Type
Output
Volume

The standard ATMOS accumulation tanks provided

TANK TYPE
AN 500
AN 750
AN 1000

Tank insulation

A suitable solution is joint mineral wool insulation of the particular number of tanks (of required
volume) placed together into a plasterboard structure, or additional filling with granular insulation.
When using the mineral wool, the specified minimum insulation thickness is 120 mm. Another option
is purchasing tanks in a leather-cloth housing insulated by mineral wool (see the price list).

Advantages

The installation with accumulation tanks provides several advantages:
-
lower fuel consumption (by 20 – 30%), the boiler operates in full output and at an optimal effec-
tiveness of 81 - 89 % until the complete combustion of the fuel
-
prolonged boiler and chimney service life – minimum formation of wood-tars and acids
-
possibility to combine it with other heating methods – accumulated electric power, solar collec-
tors
-
combination of wall radiators and floor heating
-
convenient heating and ideal fuel combustion
-
environmentally friendlier heating
24-GB
Instruction manual - GB
DC15E
DC25S
DC22S
DC18S
DC25GS
DC22SX
DC20GS
DC30SX
18
22
1000-1500
1500-2000
1500-2000
VOLUME ( l )
500
750
1000
DC40GS
DC32S
DC40SE
DC32GS
DC40SX
25
32
40
2000-2500
2500-3000
DIAMETER (mm)
600
750
850
www.atmos.cz
DC50S
DC70S
DC100
DC50SE
DC75SE
49
70
3000-4000
4000-5000
5000-6000
HEIGHT (mm)
1901
1925
2011
99