Boiler Bases - Atmos C15E Instruction Manual

15 - 75 kw
Table of Contents

Advertisement

Boilers are not suitable for burning wood with moisture content lower than 12%.
Fuel heating capacity
Wood - type
spruce
pine
birch
oak
beech
Raw wood does not burn easily, produces a lot of smoke and substantially decreases
the service life of your boiler and chimney. Boiler output drops as low as 50% and fuel
consumption doubles.

7. Boiler bases

Boiler type (mm)
DC15E/DC18S/DC22SX
DC20GS
DC22S/DC25S/DC30SX
DC30SE/DC32S/DC25GS/
DC32GS/DC40GS/DC40SX
DC40SE
DC50SE
DC50S, DC70S
DC75SE
Instruction manual - GB
Heating capacity per 1 kg
kcal
3900
3800
3750
3600
3450
A
B
600
600
700
600
600
800
700
800
700
1000
800
1000
700
1000
800
1300
www.atmos.cz
The boilers maximum output with wet fuel
illustrated in the graph
DC15 E
DC 18 S
DC 22 S
DC 25 S
DC 32 S
DC 40 S(E)
DC 50 S(E)
DC 75 S(E)
The information is relevant to other gasifica-
tion boiler types.
kJoule
16250
15800
15500
15100
14400
We recommend providing a concrete (metal)
base under the boiler.
kW
-
8
- 13
- 14
- 19
- 24
- 31
- 39
- 53
kWh
4,5
4,4
4,3
4,2
4,0
GB-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents