Description
Value Range
Default Value
Web User Interface Reference
RTP_PTIME
Value Format
Description
Value Range
Default Value
Web User Interface Reference
RTCP_ENABLE_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
Web User Interface Reference
Document Version
2012-02
Specifies the highest port number that the unit will use for RTP packets.
Note
•
If port numbers are specified in [Channel 1–25] in
4.3.6.3 External RTP Port in the Web user interface, this
setting is ignored and the corresponding external RTP port is
enabled.
1424–49150 (even number only)
Note
•
The value for this setting must be greater than or equal to
"RTP_PORT_MIN" + 400.
•
Changing this setting may affect the number of simultaneous
calls that can be made. Therefore, when setting this parameter,
be aware that the maximum number of necessary ports can be
calculated as shown below:
No. of lines ´ No. of channels ´ 2 ´ 10 (No. of terminals)
20000
Maximum RTP Port Number (Page 113)
Integer
Specifies the interval, in milliseconds, between transmissions of RTP
packets.
•
20
•
30
•
40
20
RTP Packet Time (Page 112)
RTCP_ENABLE_1, RTCP_ENABLE_2, ..., RTCP_ENABLE_6
Boolean
Selects whether to enable or disable RTCP (Real-Time Transport
Control Protocol). For details, refer to RFC 3550.
•
Y (Enable RTCP)
•
N (Disable RTCP)
N
RTCP Enable (Page 115)
5.6.2 RTP Settings
Administrator Guide
229