Description
Value Range
Default Value
Web User Interface Reference

CFG_CYCLIC_INTVL

Value Format
Description
Value Range
Default Value
Web User Interface Reference

CFG_RTRY_INTVL

Value Format
Description
Value Range
Default Value

CFG_RESYNC_TIME

Value Format
Description
Document Version
2012-02
Specifies whether the unit periodically checks for updates of
configuration files.
Y (Enable periodic synchronization of configuration files)
N (Disable periodic synchronization of configuration files)
N
Cyclic Auto Resync (Page 147)
Integer
Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
1–40320
10080
Resync Interval (Page 148)
Integer
Specifies the period of time, in minutes, that the unit will retry checking
for an update of the configuration files after a configuration file access
error has occurred.
Note
This setting is available only when "CFG_CYCLIC" is set to "Y".
1–1440
30
String
Specifies the time (hour:minute) that the unit checks for updates of
configuration files.