2.2.4 Downloading Configuration Files
Download Timing
At a specified time each day
When directed
42
Administrator Guide
After the unit is powered on, it will check for and download configuration
files once per day at the specified time.
SIP Phone
Power On
at 12:00
02:00
02:00
The configuration files are downloaded at a set time each day:
Set a time by specifying "CFG_RESYNC_TIME".
Note
If the value for "CFG_RESYNC_TIME" is any valid value other
than an empty string, the unit downloads the configuration files
at the fixed time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are
disabled.
The time is specified using a 24-hour clock ("00:00" to "23:59").
When a setting needs to be changed immediately, units can be directed to
download the configuration files by sending them a NOTIFY message that
includes a special event from the SIP server.
In the configuration file:
Specify the special event text in "CFG_RESYNC_FROM_SIP".
In the Web user interface:
Click the [Maintenance] tab, click [Provisioning Maintenance],
and then enter the special event text in [Header Value for Resync
Event].
Generally, "check-sync" or "resync" is set as the special event text.
Explanation
CFG_RESYNC_TIME="02:00"
Provisioning
Check
Download
Check
Download
Check
Download
Server
Document Version
2012-02