5.5.2 Tone Settings
Description
Value Range
Default Value
DIAL_TONE1_RPT
Value Format
Description
Value Range
Default Value
DIAL_TONE1_TIMING
Value Format
Description
Value Range
Default Value
Web User Interface Reference
DIAL_TONE2_FRQ
Value Format
Description
Value Range
Default Value
DIAL_TONE2_GAIN
Value Format
206
Administrator Guide
Specifies the gain, in decibels, of Dial Tone 1.
-24–6
0
Integer
Specifies whether Dial Tone 1 is repeated.
0–1
–
0: No Repeat
–
1: Repeat
0
Comma-separated Integer
Specifies the pattern, in milliseconds, of Dial Tone 1 using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Infinite time)
Note
•
Avoid setting 1–50 for any of the values.
60,0
Tone Timings (Page 134)
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of Dial Tone 2 using 2
whole numbers separated by a comma.
0, 200–2000 (0: No tone)
350,440
Integer
Document Version
2012-02