Siemens SISTORE AX4 Lite 1000/100 Configuration & Operation Manual page 53

Table of Contents

Advertisement

Siemens AG
2.
Highlight the box beside Disk Almost Full Notify, and press the
Î
Select the percentage level of disk usage at which you want the DVR to trigger
an alert. Percentage levels range from 80% to 99%.
3.
Highlight the first box beside Disk S.M.A.R.T., and press the
4.
Use the Up and Down arrow buttons to scroll through the numbers. Refer to the
hard disk drive manufacturer's documentation for the correct temperature
setting.
Î
If the temperature of hard disk drive exceeds the defined threshold, the system
triggers an alert.
5.
Highlight the second box beside Disk S.M.A.R.T., and press the
6.
Select either ºC (Celsius) or ºF (Fahrenheit), and press the
7.
Highlight the Actions tab and the System Event Actions screen displays.
Fig. 47
System Event Actions screen
Actions
The DVR can be set to react to system events. System events can activate the
Alarm-Out connector, sound the DVR's internal buzzer, and/or notify a number of
different devices.
1.
Highlight the Alarm-Out box beside the desired event (Check Recording,
Check Alarm-In, Disk Almost Full, Disk Full, Disk Bad, Disk Temperature, or
Disk S.M.A.R.T.), and press the
2.
Select between Alarm Output connector and the DVR's internal buzzer that you
would like to activate and to sound whenever the DVR detects event.
NOTE
The Alarm-Out action cannot be set to System and Panic Record events.
3.
Highlight the Notify box beside the desired event (System, Panic Record,
Check Recording, Check Alarm-In, Disk Almost Full, Disk Full, Disk Bad, Disk
Temperature, or Disk S.M.A.R.T.), and press the
button.
button.
Configuration
button.
button.
button.
button.
53
06.2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents