Notes
Possible temperature setting ranges in the operation
mode are as follows:
Cool, Dry, Auto ............... 18 to 30 °C (64 to 88 °F)
Heat ............................... 16 to 30 °C (60 to 88 °F)
If the temperature out of the Set temp. range limitation
is set, it will be reset at the nearest temperature within
the range. However, the adjusted temperature value
in this setting will not be corrected automatically.
(7) Select [Zone (single)] (individual setting of zone control)
or [Zone (group)] (simultaneous setting of zone control)
as follows:
Individual setting of zone control):
Select [Zone (single)] with the [Cursor button (Up/
Down)]. Then press the [Cursor button (Right)] to move
the cursor to next setting item.
Weekly timer setting
Weekly
Su Mo
1
5 00
Day
Zone ( sin g le )
1
Time
End
Cancel:
OK:
Time 8
Select the room-temperature sensor with the [Cur-
sor button (Up/Down)]. Then press the [Cursor button
(Right)] to move the cursor to next setting item.
Weekly timer setting
Weekly
Su Mo
1
5 00
Day
Zone ( sin g le ) Sensor
1
Time
End
Cancel:
OK:
Time 8
Select applicable zone name with the [Cursor button
(Left/Right)], and press the [Cursor button (Up/Down)]
to mark a check.
Check-marked: The zone is air-conditioned.
Blank: The zone is not air-conditioned.
Weekly timer setting
Weekly
Su Mo
1
5 00
Day
Zone ( sin g le ) Sensor: Secondary RC
Zone 1
1
Time
End
Cancel:
OK:
Time 8
After you select all the applicable zones, press the
[Enter button] to complete the individual setting of zone
control.
Mo 10:00
On
Heat 20
° C
Sensor:
Time 2
Mo 10:00
Heat 20
On
° C
Secondar y RC
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Time 2
Mo 10:00
Heat 20
On
° C
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Time 2
Notes
When you set "On timer", you need to set all of
operating mode, temperature, room-temperature
sensor, and applicable zone(s).
Without these configurations, the timer will not work.
Depending on the initial setup in the installation, there
is a case that at least one zone need to be selected.
In that case, following message is displayed on the
screen, and you need to put a check mark at least one
zone
One zone must be open at all times.
XXXXXX
Simultaneous setting of zone control):
Select [Zone (group)] with the [Cursor button (Up/
Down)]. Then press the [Cursor button (Right)] to move
the cursor to next setting item.
Weekly timer setting
Weekly
Su Mo
1
5 00
Day
Zone (group)
1
Time
End
Cancel:
OK:
Time 8
Select the applicable group with the [Cursor button (Up/
Down)].
Weekly timer setting
Weekly
Su Mo
1
5 00
Day
Zone (group)
1
Time
End
Cancel:
OK:
Time 8
To complete the simultaneous setting of zone control,
press the [Enter button].
Weekly timer setting
Weekly
Su Mo
1
5 00
Day
Zone ( group )
1
Time
End
Back:
Setting:
Time 8
(8) When setting the other days of the week continually,
perform procedures in step 4 and 5.
XXXXXX
Mo 10:00
On
Heat 20
° C
Time 2
Mo 10:00
On
Heat 20
° C
Day
Time 2
Mo 10:00
On
Heat 20
° C
Day
Time 2
En-20