Fujitsu ARTG24LM Operating Manual

Duct type
Hide thumbs

Advertisement

Quick Links

OPERATING MANUAL

AIR CONDITIONER

Duct Type

Indoor Unit
ARTG24LM
KEEP THIS MANUAL FOR FUTURE REFERENCE
PART NO. 9374379606

Advertisement

loading

  Related Manuals for Fujitsu ARTG24LM

  Summary of Contents for Fujitsu ARTG24LM

  • Page 1: Operating Manual

    OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG24LM KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379606...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS........2 TEMPERATURE SET BACK TIMER......11 FEATURES AND FUNCTIONS ....... 3 ECONOMY OPERATION ........12 NAME OF PARTS ........... 4 CLEANING AND CARE......... 12 PREPARATORY OPERATION ........ 5 TROUBLESHOOTING .......... 13 OPERATION ............6 OPERATING TIPS..........14 TIMER FUNCTIONS ..........8 SELF-DIAGNOSIS ..........
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS This appliance is not intended for use by persons (including children) with reduced physical, CAUTION given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. the unit or the power plug during thunderstorm.
  • Page 4: Name Of Parts

    NAME OF PARTS Remote controller START/STOP button Operation lamp SET TEMP. (temperature) button Operation mode indicator MODE button FAN button Fan speed indicator ECONOMY button Temperature indicator TIMER MODE (CLOCK AD- JUST) button Function indicator DAY (DAY OFF) button Defrost indicator Thermo sensor indicator SET BACK button SET TIME ( <...
  • Page 5: Preparatory Operation

    PREPARATORY OPERATION Set the current day and time Press the DAY button and select the current day. appears around the selected day. Press the TIMER MODE (CLOCK ADJUST) button for 2 seconds or more. The time indicator on the Press the SET TIME (< >) buttons to set the current time. Press repeatedly to adjust the current time in 1-minute incre- ments.
  • Page 6: Operation

    OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To start/stop operation Press the START/STOP button. Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit To set the operation mode Operation mode setting Press the MODE button to set the operation mode.
  • Page 7 OPERATION Room temperature sensor selection ice personnel when using this function. Indoor unit Press the ECONOMY button for more than 2 seconds to select whether the room temperature is detected at the indoor unit or the remote controller. When the thermo sensor indicator appears, the room temperature is detected at the remote controller.
  • Page 8 TIMER FUNCTIONS OFF timer (See page 8.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 8.) Use this timer function to start air conditioner operation.
  • Page 9 WEEKLY TIMER Press the TIMER SET button for 2 seconds or more. For ALL, all of the days can be set together when a appears around each day. Time setting When the operating time is set, ON-1 OFF-1 ON-2 OFF-2 ex.
  • Page 10 WEEKLY TIMER WEEKLY timer operation To start To cancel Press the TIMER DELETE button to ex. Operating time 7:00-18:00 timer starts automatically. cancel the timer mode. The timer mode can also be The operating time for the current canceled by changing the timer day is displayed.
  • Page 11 TEMPERATURE SET BACK TIMER Temperature SET BACK timer setting SET BACK If there is no existing SET BACK tempera- ture setting, “- -” will be displayed for the temperature. Press the SET BACK button to change to the SET BACK con- Press the TIMER SET button for 2 seconds or more.
  • Page 12: Cleaning And Care

    ECONOMY OPERATION Begin air conditioner operation before performing this procedure. To Use the ECONOMY Operation Press the ECONOMY button. The ECONOMY indicator will light. ECONOMY operation begins. To Stop the ECONOMY Operation Press the ECONOMY button again. The ECONOMY indicator will go out. Normal operation begins.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical WARNING Merely turning off the unit’s power switch will not completely disconnect the unit from the power Symptom Problem Page...
  • Page 14: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Microcomputer-controlled Automatic Defrosting* This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat When using the heating mode under conditions of low out- indoors.
  • Page 15 OPERATING TIPS Mode operation AUTO (in COOLING model): minutes, during which time the indoor unit detects the room conditions and selects the proper mode. Cooling mode or Dry mode temperature in temperature Monitor operation setting When the indoor unit has adjusted your room’s temperature to near the temperature setting, it will begin monitor oper- ation.
  • Page 16: Self-Diagnosis

    OPERATING TIPS AUTO Restart In Event of Power Interruption If the power supply to the air conditioner is interrupted by a Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air power failure, the air conditioner will restart automatically in conditioner to malfunction.