For [Enable/Disable setting], select [Enable] or [Disable]
3
with the [Cursor button (Up/Down)], and press the [Enter
button] to complete the setting.
Set temp. auto return
Mo 10:00
Enable
Enable/Disable setting
Return time and temp. setting
Time
/
Temp.
Cool/Dry
30min.
/ /
26
° C
Heat
30min.
/
26
° C
Cancel:
OK:
Air flow dire...
Set temp. range
For [Return time and temp. setting], select operation
4
mode with the [Cursor button (Up/Down)], and press
the [Enter button]. Adjust the value with the [Cursor but-
ton (Up/Down)].
With the [Cursor button (Left/Right)], the cursor can be
switched [Time] and [Temp].
Set temp. auto return
Mo 10:00
Enable/Disable setting
Enable
Return time and temp. setting
Time
/
Temp.
Cool/Dry
30min.
26
° C
26
Heat
30min.
° C
Cancel:
OK:
Air flow dire...
Set temp. range
To complete the setting, press the [Enter button]. To re-
turn to the “Function” screen, press the [Cancel button].
Notes
• The set time can be set from 30 to 120 minutes in
units of 10 minutes.
• Possible temperature setting ranges in the operation
mode are as follows:
Cool, Dry .......................... 18 to 30 °C (64 to 88 °F)
Heat .................................. 16 to 30 °C (60 to 88 °F)
• If any ranges have been set in [Set temp. range]
setting, adjustable temperature range in this setting
follows the restricted range.
• If you set any ranges in the [Set temp. range] setting
after setting of [Set temp. auto return], the restricted
range set in the [Set temp. range] also overrides [Set
temp. auto return] setting.
• Even if the temperature setting change is done on
the secondary remote controller, it returns to the set
value in [Set temp. auto return] on the primary remote
controller.
When you return to the “Monitor” screen, the icon is displayed.
To check the function, press the [Enter button] and select the
icon with the [Cursor button (Left/Right)].
Monitor
Mo 10:00
Set temp. auto return: Remaining 30 minutes
24
° C
Cool
High
End:
Menu

3-2-3. Set temp. range limitation setting

In “Function” screen, select [Set temp. range] with the
1
[Cursor button (Up/Down)].
Function
Mo 10:00
Air flow direction
Off
Economy
Set temp. auto return
Disable
Set temp. range
Disable
Back:
Setting:
Timer
To change the setting, press the [Enter button].
“Set temp. range” screen is displayed.
2
Set temp. range
Mo 10:00
Enable/Disable setting
Disable
Temp. setting
Lower
Upper
Cool/Dry
18
30
° C
° C
16
30
Heat
° C
° C
Auto
18
30
° C
° C
Back:
Setting:
Air flow dire...
Set temp. au...
Select the item with the [Cursor button (Up/Down)], and
press the [Enter button].
For [Enable/Disable setting], select [Enable] or [Disable]
3
with the [Cursor button (Up/Down)], and press the [Enter
button] to complete the setting.
Set temp. range
Mo 10:00
Enable/Disable setting
Enable
Temp. setting
Lower
Upper
Cool/Dry
18
30
° C
° C
16
Heat
30
° C
° C
Auto
18
30
° C
° C
Cancel: