2-2. Setting items in Menu

Monitor
Mode
Set temp.
26
Cool
Menu
Following items can be adjusted in Menu.
NOTES:
Functions marked "–" in "Secondary unit" column of following table cannot be adjusted from the remote controller that is
specified as the secondary control unit. Adjust the function on the primary unit.
Depending on the type of the indoor unit, some functions cannot be set.
Settings and Display Items
Function
Economy
Set temp. (temperature)
auto return
Set temp. (temperature)
range limitation
Timer
On timer
Off timer
Weekly timer
Auto-off timer
NOTE: If the function you are selecting is restricted by [Management] function, following message is displayed in the operation
guidance display.
En-9
Menu
Mo 10:00
Fan
° C
High
Back:
The room temperature will be little higher than the set-temp under
cooling mode and lower than set-temp under heating mode.
Therefore, the economy mode is able to save more energy than
other normal mode.
The temperature automatically returns to the preset value after a
certain period of time has elapsed since the set temperature was
changed.
The set time can be set from 30 to 120 minutes in units of 10 min-
utes.
Limits the range of the set temperature.
The temperature range can be limited through the operation mode.
Use this timer function to start air conditioner operation. The timer
operates and air condition operation starts after the set time has
passed. The timer can be set up to 24 hours in advance.
Can be set up to 24 hours in units of 30 minutes.
Use this timer function to stop air conditioner operation. The timer
operates and air conditioner operation stops after the set time has
passed. The timer can be set up to 24 hours in advance.
Can be set up to 24 hours in units of 30 minutes.
Operation start and end times can be set to 1 week.
Up to 8 patterns of On/Off, operation mode, and temperature setting
can be set in 1 day.
2 sets of the weekly timer, [Weekly 1] and [Weekly 2], can be set.
For example, you can assign the [Weekly 1] for summer and [Weekly
2] for winter. Then you only need to switch [Weekly 1] and [Weekly 2]
by the season.
Operation end time can be set if the air conditioning operation has
been started with the [On/Off button] of this remote controller.
The set time can be set from 30 to 240 minutes in units of 10 min-
utes.
You can also specify the valid hour in a day for this timer.
Back:
XXXXXX
Mo 10:00
Function
Timer
Setting:
Submenu
Details
Restricted by the management function
XXXXXX
Submenu
[
1/2
]
Mo 10:00
Date and time
Screen
Filter sign
R.C. sensor control
Room temp. display
Back:
Setting:
Monitor
Operation
Secondary
(See page)
12
12
13
14
15
16
22
Off
Off
unit
O