HOW A HOT -WATER SYSTEM OPERATES
Your entire heating system (boiler, piping and radiation
units) is filled with water. As the water in the boiler is
heated, it is pumped from the top of the boiler through
the supply main to the radiation units. The cooler
water in them flows back through the return main to
the boiler. This provides positive and rapid response
to the thermostat.
FILLING SYSTEM WITH WATER
Close the Air Vents on all radiation
units. Open
the Valves to these units. Make sure the boiler
and Expansion Tank Drain Cocks are closed. The
Air Bleed Screw on the tank Drain Fitting should
be closed.
Open
the valve in the line from the
boiler
to the expansion
tank (see page
15 for
additional
information).
Open the water
inlet to
your boiler and leave it open. Start with the lowest
radiation unit. Open the air vent on this unit. When
all the air has escaped
and water
starts to flow
from the vent, close it. Go to the next radiation
unit, and repeat this process.
Repeat
until you
have covered every radiation
unit in the system
(ending
up at the highest
unit in the system).
If
your
units have automatic
vents,
this manual
venting
is unnecessary
but it will speed
up the
proper filling of your system.
If your system is a closed expansion tank system,
you may have an Automatic
Fill Valve. You may
leave it open to refill the system automatically
as
needed. Check the temperature-pressure
gauge.
Note the position of the hand indicating
pressure.
This should
be between
10 and
15 Ibs. Any
lowering
of this movable
hand below 10 Ibs. will
indicate
loss
of water
due to leakage.
The
automatic
fill valve should
compensate
for this.
Instructions
are packaged
with the valve.
WARNING-Never
run water into a hot empty
boiler. I
1. This appliance is equipped with an ignition device
which automatically
lights the burner.
Do not
attempt to light the burner by hand.
WARNING:
If you
do
not follow
these
instructions
exactly,
fire or explosion
may
resultwith
property damage, personal injury,
or loss of life.
2. BEFORE
OPERATING
smell all around
the
appliance
area for gas. Be sure to smell next to
the floor because
some gas is heavier than air
and will settle on the floor.
WARNING:
IF YOU SMELL GAS:
Do not attempt to operate any appliance,
do
not touch any electrical
switch,
do not use
the phone.
Leave the building immediately
and call your
gas supplier.
If your gas supplier
cannot be reached,
call
the fire department.
3. WARNING:
When turning or depressing
the
gas control knob, use only your hand to push
down or turn the knob. Never use tools. If
the knob will not operate by hand, the control
must
be replaced
by a qualified
service
technician.
Force or attempted
repair may
result in a fire or explosion.
4. WARNING:
If any part of this appliance
has
been
under
water,
do
not
operate.
Immediately call a qualified service technician
to inspect the appliance
and to replace any
part of the gas control system which has been
under water.