Dunkirk XEB-2 Installation Instructions Manual page 2

Gas-fired hot water induced craft boilers
Table of Contents

Advertisement

ASME
RELIEF
VALVE
!I-,L
;_
I
I
L
I
I
I
I
I
I
LEFT SIDE
DRAIN
VALVE
A
TEMPERATURE
FRONT
SUPPLY
COMBINATION
LIMIT & RELAY
CONTROL
l
29
SWITCH
1
PRESSURE
I
_
SWITCH
[:!_
INTERMITTENT
[= ,LOTCO.T.OL
V%E
L
RIGHT SIDE
®
4,+
DESIGN
CERTIFIED
FOR
NATURALAND
PROPANE
GAS
Model
XEB-2
XEB-3
XEB-4
XEB-5
XEB-6
XEB-7
NO.
Sec.
2
3
4
5
6
7
NATURAL AND PROPANE GASES
AGA/CGA
Input
*MBH
42.5
75
112.5
150
187.5
225
Heating
Capacity
+MGB
36
63
94
125
155
186
Net IBR
Rating
*MBH
31
55
82
109
135
162
Width
A
11
14¼
17½
20¾
24
27¼
To Chimney
(Category I)
4
4
4
4
4
4
Vent Diameter(INCHES)
Horizontal Vent
(Category III)
3
3
3
3
3
3
*MBH = 1,000 Btuh = British Thermal Unit Per Hour
Boilers are equipped for altitudes up to 2,000 feet only,
USA
Only - For altitudes above 2,000 feet, ratings should be reduced at the rat of 4% for each 1,000 feet above sea level,
Canada Only - Boilers may be used at high altitude by using a certified field conversion, kit, resulting in a 10% derate,
+ Heating Capacity based on DOE,
(Department of Energy) test procedure,
New York City MEA Number 484-84-E
Vol. IV.
The Ratings marked "Net 1=B=R Ratings" indicate
the amount
of remaining
heat input that can be
used to heat the radiation
or terminal
units. The
Net I=B=R
Ratings
shown
are based
on an
allowance
of 1.15 in accordance
with the factors
shown on the I=B=R
Standard
as published
by
The Hydronics
Institute.
Selection
of boiler
size should
be based
upon
"Net I=B=R
Rating"
being
equal
to or greater
than the calculated
heat loss of the building.
The manufacturer
should
be consulted
before
selecting
a boiler for installations
having unusual
piping and pickup requirements.
These boilers
must stand on a noncombustible
floor.
If installed
on a combustible
floor,
use
Combustible
Floor Base.
These
Gas-Fired
Hot Water
Boilers
are
low
pressure,
sectional
cast
iron boilers
Design
Certified
by
CSA
(Canadian
Standards
Association)
for use with Natural
and Propane
Gases. They are constructed
and hydrostatically
tested for a maximum
working pressure
of 50psi
(pounds
per square
inch) in accordance
with
A.S.M.E.
(American
Society
of Mechanical
Engineers)
Boiler
and Pressure
Vessel
Code
Section IV Standards for cast iron heating boilers.
BOILERS
FOR USE AT HIGH ALTITUDE
This boiler is factory equipped
for use at altitudes
of 0-2,000 feet above sea level. For use at altitudes
above 2,000 feet above sea level, the input ratings
are reduced by a change in main burner orifice size.
U.S.A. Only - For altitudes above 2,000 feet above
sea level, input ratings should be reduced
at the
rate of 4% for each 1,000 feet above sea level.
Consult the National Fuel Gas Code (NFPA54/ANSI
Z223.1-1atest
edition),
or the manufacturer
for
correct
orifice
sizing
information.
High altitude
orifices are available from the boiler manufacturer.
Canada
Only - For altitudes in the range of 2,000-
4,500 feet above sea level, boilers may be field
equipped for use at high altitude by using a certified
field conversion kit. The change in main burner orifice
size results in the boiler's input rating being reduced
by 10%.The conversion
shall be carried out by a
manufacturer's
authorized
representative,
in
accordance with the requirements of the manufacturer,
p rovi ncial or territorial a uth orities having j urisd iction
and in accordance with the requirements of the CSA-
B149.1
and CSA-8149.2
Installation
Codes.The
certified field conversion kit includes a conversion data
plate, which must be attached to the boiler adjacent to
the rating plate, indicating that the boiler
has been
converted
for high altitude
use. The conversion
data
plate
must
be filled
in with the correct
conversion
information.