To meet NEC compliance, the largest PV array that can be connected to the MX60 should have a
rated short-circuit current of 48 amps. The following charts show the maximum distance of various
gauge two-conductor copper wire from the PV array to the MX60 with a 1.5% maximum voltage
drop. Temperature and conduit fi ll corrections may be required. Using a higher voltage PV array
with a low voltage battery system allows you to use a much smaller wire size or go up to 5 times as
far with the same gauge wire.

Wire Distance Chart

12 Volt PV Array
16V MPP Typical
Distance in Feet
1.5% Voltage Drop
12 Volt Battery System
24 Volt PV Array
32V MPP Typical
Distance in Feet
1.5% Voltage Drop
12 or 24 Volt Battery
48 Volt PV Array
64V MPP Typical
Distance in Feet
1.5% Voltage Drop
12, 24 or 48 Volt Battery
80
(Two Wires)
(Two Wires)
System
(Two Wires)
System
Wire Gauge
#8
#6
#4
8
22
35
57
10
18
28
45
15
12
19
30
20
9
14
22
30
6
9
15
40
4
7
11
50
3
5
9
Wire Gauge
#8
#6
#4
8
45
71
114
10
36
57
91
15
24
38
60
20
18
29
45
30
12
19
30
40
9
14
23
50
7
11
18
Wire Gauge
#8
#6
#4
8
90
142
228
10
72
114
182
15
48
76
120
20
36
58
90
30
24
38
60
40
18
28
46
50
14
22
36
#2
#1/0
#2/0
#4/0
90
145
180
290
72
115
145
230
48
76
96
150
36
57
72
116
24
38
48
77
18
29
36
56
4
23
29
46
#2
#1/0
#2/0
#4/0
180
290
360
580
145
230
290
460
96
153
192
300
72
115
145
232
48
77
97
154
36
58
72
112
29
46
58
86
#2
#1/0
#2/0
#4/0
360
580
720
1160
290
460
580
920
192
306
384
600
144
230
290
464
96
154
194
308
72
116
144
224
58
92
116
172