60 Volt PV Array
80V MPP Typical
Distance in Feet
(Two Wires)
1.5% Voltage Drop
12, 24 or 48 Volt Battery
System
72 Volt PV Array
96V MPP Typical
Distance in Feet
(Two Wires)
1.5% Voltage Drop
12, 24 or 48 Volt Battery
System
OutBack Power Systems Inc.
Wire Gauge
#8
#6
#4
8
112
177
285
10
90
142
227
15
60
95
150
20
45
72
112
30
30
47
75
40
22.5
35
57
50
17.5
27
45
Wire Gauge
#8
#6
#4
8
140
221
356
10
113
178
284
15
75
119
188
20
56
90
140
30
37
59
94
40
28
44
71
#2
#1/0
#2/0
#4/0
450
725
900
1450
362
575
725
1150
240
382
480
750
180
287
362
580
120
192
230
385
90
145
180
280
72
115
145
215
#2
#1/0
#2/0
#4/0
562
906
1125
1812
453
719
906
1437
300
478
600
937
225
359
452
725
150
240
287
481
112
181
225
350