Battery Voltage Screen
BATTERY VOLTAGE
12
24
36
48
^^
EXIT
ENTER
Verifi cation Screen
Are you sure?
12
24
36
48
^^
NO
Power-Up Screen
OutBack
Power
Systems
MX60
OutBack Power Systems Inc.
Press the " " soft key to select a battery voltage. The
MX60's default values are based on a 12 VDC system.
60
Selecting a higher voltage system will change all the
default values (e.g., the values will double with a 24
VDC system, triple with a 36 VDC system, etc.). "^^"
indicates the chosen voltage. The MX60 will automat-
ically accept the selected battery voltage if left unat-
tended for 5 minutes in this screen. After choosing
the voltage, press the <ENTER> soft key to proceed.
Press the <YES> soft key to proceed if the selected
battery voltage is correct. If incorrect, press <NO> to
60
re-enter the correct voltage.
Yes
The MX60 briefl y returns to the Power-Up screen and
12V
then automatically opens the STATUS screen which
displays information regarding the recharging status.
Confi rm the battery voltage displayed in the upper
right corner is correct.
Note: Repeating the Powering Up sequence resets
the MX Charge Controller to its factory default
settings.