EXIT NEXT +VOC +Min
Charger Aux
Eq
Logging
EXIT
48
ADVANCED MENU

Wakeup Mode

01.5v 05m
Light
Misc *Advanced
Log2
GO
Wakeup Mode selects how often the MX60 does a
"Wakeup" during "Snoozing" periods. Since environ-
mental condition impact the open circuit voltage
(Voc) of an array, a user selectable Voc rise in value
will allow the controller to "wakeup" sooner or later
based on the last measured Voc value. A selectable
delay time in minutes will also allow the control-
ler to "Wakeup" sooner or later if the measured Voc
did not meet the user selectable Voc rise in value.
Before changing these values, monitor your system
for a week or so using the factory defaults and then
gradually adjust the set points. If they're set too high,
the MX60 might not wake up soon or often enough,
which means a loss of power production. Note:
+VOC ranges from 1.5V up to 9.5V. +MIN ranges from
5 up to 15 minutes. Press the <EXIT> soft key to
return to the MAIN Menu.
From the MAIN Menu, press the < > soft key to
move the asterisk next to the Logging function and
then press the <GO> soft key.