Secondary LOG2 Screen

The Secondary Log2 screen shows the basic recharging state of the MX60 (EQ, FLOAT) time in min-
utes, and the daily maximum (HighWatts) wattage seen by the MX60 during the day.
When initiated, EQ
information will be
displayed here.
The lower and upper
battery temperature
compensation voltage
is visible and active
only when the
mode is set to LMIT
(5.11 Rev.).
Note: Float time does not accumulate (1) when the MX60 is sleeping or (2) when an external
power source keeps the battery above fl oat voltage.
OutBack Power Systems Inc.
0000 fl oat Tmin
0705 HighWatts
Lo 13.2 Hi 14.8
BACK
DCkWh
Press soft key #3 to display the accumulated total
kWh reading in AC or DC the Data
Logging screen.
• DCkWh (default) shows DC kiloWatthours and
should be used in a non grid tied system.
• ACkWh is used with a grid tied system. The
heading in the logging screen will change to
"TotalKWh AC". TotalKWh AC is based on a 90%
inverter effi ciency (1kWH DC = 0.9kWH AC).
The present day's time—
in minutes—spent in
Float stage.
This value is the peak
daily Watts seen by the
MX60.